Content

Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs.

Description

Nelson G, Yoon S, Krishna G, Wilfley B, Fahrig R., Med Phys. 40(11):111917. doi: 10.1118/1.4826159., 2013 Nov 01

Investigators

Ganesh Krishna, M.D.

Abstract

PURPOSE: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.

METHODS: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.

RESULTS: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient location. When tumor SNR is held constant (i.e., x-ray fluence is scaled appropriately), SBDX gives 2-10 times less dose than fluoroscopy for the same conditions within the typical range of patient locations. The relative position of the patient (as a percent of SDD) has a much more significant impact on dose than either SDD or patient position. The patient position providing the minimum dose for a given tumor SNR and SDD is approximately the same as the position of maximum tomographic angle.

CONCLUSIONS: SBDX offers a significant dose advantage over currently used C-arm fluoroscopy. The patient location with lowest dose coincides with the location of maximum tomographic angle. In order to provide adequate space for the patient and for the pulmonologists' equipment, a SDD of 100 cm is recommended.

Pubmed Abstract

Pubmed AbstractOpens New Window

Associated Topics

  • Lung Diseases

Related Publications

Does SLE widen or narrow race/ethnic disparities in the risk of five co-morbid conditions? Evidence from a community-based outpatient care system.

Falasinnu T, Chaichian Y, Li J, Chung S, Waitzfelder BE, Fortmann SP, Palaniappan L, Simard JF.
Lupus. 28(14):1619-1627. doi: 10.1177/0961203319884646. Epub 2019 Oct 29.
2019 Dec 01

Improved targeting accuracy of lung tumor biopsies with scanning-beam digital x-ray tomosynthesis image guidance.

Nelson G, Wu M, Hinkel C, Krishna G, Funk T, Rosenberg J, Fahrig R.
Med Phys. 43(12):6282.
2016 Dec 01

The burden of cancer in Asian Americans: a report of national mortality trends by Asian ethnicity.

Thompson CA, Gomez SL, Hastings KG, Kapphahn K, Yu P, Shariff-Marco S, Bhatt AS, Wakelee HA, Patel MI, Cullen MR, Palaniappan LP.
Cancer Epidemiol Biomarkers Prev. 25(10):1371-1382.
2016 Oct 01

Effect of endobronchial coils vs usual care on exercise tolerance in patients with severe emphysema: the RENEW randomized clinical trial.

Sciurba FC, Criner GJ, Strange C, Shah PL, Michaud G, Connolly TA, Deslée G, Tillis WP, Delage A, Marquette CH, Krishna G, Kalhan R, Ferguson JS, Jantz M, Maldonado F, McKenna R, Majid A, Rai N, Gay S, Dransfield MT, Angel L, Maxfield R, Herth FJ, Wahidi MM, Mehta A, Slebos DJ; RENEW Study Research Group.
JAMA. 315(20):2178-2189. doi: 10.1001/jama.2016.6261.
2016 May 24

Electromagnetic navigational bronchoscopy spares a drunken crab from the surgeon's knife.

Parikh MS, Seeley E, Krishna G.
J Bronchology Interv Pulmonol. [Epub ahead of print]
2016 Apr 11
The Sutter Health Network of Care
Expertise to fit your needs
Primary Care

Check-ups, screenings and sick visits for adults and children.

Specialty Care

Expertise and advanced technologies in all areas of medicine.

Emergency Care

For serious accidents, injuries and conditions that require immediate medical care.

Urgent Care

After-hours, weekend and holiday services.

Walk-In Care

Convenient walk-in care clinics for your non-urgent health needs.

About Sutter

  • About Our Network
  • Annual Report
  • Awards
  • Community Benefit
  • Contact Us
  • News
  • Giving
  • Find Care

  • Birth Centers
  • Care Centers
  • Emergency Rooms
  • Hospitals
  • Imaging
  • Labs
  • Surgery Centers
  • Urgent Care
  • Walk-In Care
  • View All >
  • Featured Services

  • Behavioral Health
  • Cancer Services
  • Family Medicine
  • Home Health and Hospice
  • Orthopedics
  • Pediatrics
  • Pregnancy
  • Primary Care
  • Women's Health
  • View All >
  • Patient Resources

  • Accepted Health Plans
  • Classes and Events
  • Estimate Costs
  • Health and Wellness
  • Medical Records
  • Medicare Advantage
  • My Health Online
  • Pay a Bill
  • Symptom Checker
  • Our Team

  • For Employees
  • Physician Careers
  • Recruiting Events
  • Residencies and Fellowships
  • Sutter Careers
  • Vendors
  • Volunteers
    • ADA Accessibility
    • Contact
    • Privacy
    • Do Not Sell My Personal Information

    • LinkedIn Opens new window
    • YouTube Opens new window
    • Facebook Opens new window
    • Twitter Opens new window
    • Glassdoor Opens new window
    • Instagram Opens new window

    Copyright © 2022 Sutter Health. All rights reserved. Sutter Health is a registered trademark of Sutter Health ®, Reg. U.S. Patent & Trademark office.

    Cookie Policy

    We use cookies to give you the best possible user experience. By continuing to use the site, you agree to the use of cookies. Privacy Policy Cookie Preferences

    Privacy Policy Cookie Preferences