---
title: "Off-reson-robust velocity-selective magnetizatn prep for MRA | Sutter Health"
description: "Non-contrast-enhanced MRA using the new VS magnetization preparation can reliably provide high angiographic contrast in the lower extremities with significantly improved immunity to field inhomogeneity."
url: "https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480"
---

1.  [Home](https://www.sutterhealth.org/) /
2.  [Research](https://www.sutterhealth.org/research) /
3.  [Research publications](https://www.sutterhealth.org/research/publications) /
4.  Off-reson-robust velocity-selective magnetizatn prep for MRA

# Off-resonance-robust velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.

Shin T, Hu BS, & Nishimura DG.

_Magn Reson Med. 70(5):1229-40. doi: 10.1002/mrm.24561. Epub 2012 Nov 28._

2013-11-01

## Abstract

PURPOSE: To develop a new velocity-selective (VS) excitation pulse sequence which is robust to field inhomogeneity, and demonstrate its application to non-contrast-enhanced peripheral MR angiography (MRA).

METHODS: The off-resonance-robust VS saturation pulse is designed by incorporating 180° refocusing pulses into the k-space-based reference design and tailoring sequence parameters in a velocity region of interest. The VS saturation pulse is used as magnetization preparation for non-contrast-enhanced peripheral MRA to suppress background tissues but not arterial blood based on their velocities. Non-contrast-enhanced peripheral MRA using the proposed VS preparation was tested in healthy volunteers and a patient with arterial stenosis.

RESULTS: Calf angiograms obtained using the new VS preparation show more uniform background suppression than the reference VS preparation, as demonstrated by larger mean values and smaller standard deviations of artery-to-vein and artery-to-muscle contrast-to-noise ratios (71.0 ± 11.4 and 75.3 ± 12.1 versus 61.7 ± 22.7 and 58.5 ± 27.8). Two-station peripheral MRA using the new VS preparation identifies stenosis of the femoral and popliteal arteries in the patient, as validated by digital subtraction angiography.

CONCLUSION: Non-contrast-enhanced MRA using the new VS magnetization preparation can reliably provide high angiographic contrast in the lower extremities with significantly improved immunity to field inhomogeneity.

[PubMed abstract](http://www.ncbi.nlm.nih.gov/pubmed/23192893)

![Bob S Hu, M.D.](https://dyn.mktgcdn.com/p/OLtyV-80yDbOmh0GcQI3xnNzxEtgLP1RmJcZvvKP3u4/fit=crop,gravity=auto,dpr=2,width=188,height=250,quality=100)

Bob S Hu, M.D.

Principal investigator

[View profile](https://www.sutterhealth.org/research/investigators/bob-s-hu-md-1049681033)

## Research topics

-   [Cardiovascular Diseases](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Cardiovascular+Diseases%5C%22%22)
-   [Disease Management](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Disease+Management%5C%22%22)

## Related publications

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

-   Publication
    
    ### [Antiplatelet therapy use after discharge among acute myocardial infarction patients with in-hospital bleeding.](https://www.sutterhealth.org/research/publications/antiplatelet-tx-post-discharge-ami-pts-1055312976)
    
    Wang TY, Xiao L, Alexander KP, Rao SV, Kosiborod MN, Rumsfeld JS, Spertus JA, Peterson ED.
    
    Circulation. 118(21):2139-45. doi: 10.1161/CIRCULATIONAHA.108.787143. Epub 2008 Nov 3.
    
    2008 Nov 18
    
-   Publication
    
    ### [High-resolution variable-density 3D cones coronary MRA.](https://www.sutterhealth.org/research/publications/high-resolution-vary-density-3d-cones-coronary-mra-1055312425)
    
    Addy NO, Ingle RR, Wu HH, Hu BS, Nishimura DG.
    
    Magn Reson Med. 74(3):614-21. doi: 10.1002/mrm.25803. Epub 2015 Jul 14.
    
    2015 Sep 01
    
-   Publication
    
    ### [Combined outer volume suppression and T2 preparation sequence for coronary angiography.](https://www.sutterhealth.org/research/publications/outer-vol-suppressn-t2-prepseq-ht-angiography-1055312448)
    
    Luo J, Addy NO, Ingle RR, Hargreaves BA, Hu BS, Nishimura DG, Shin T.
    
    Magn Reson Med. 74(6):1632-9. doi: 10.1002/mrm.25575. Epub 2014 Dec 17.
    
    2015 Dec 01
    
-   Publication
    
    ### [Cardiovascular magnetic resonance phase contrast imaging.](https://www.sutterhealth.org/research/publications/cardiovasc-mri-phase-contrast-1055312458)
    
    Nayak KS, Nielsen JF, Bernstein MA, Markl M, D Gatehouse P, M Botnar R, Saloner D, Lorenz C, Wen H, S Hu B, Epstein FH, N Oshinski J, Raman SV.
    
    J Cardiovasc Magn Reson. 17(1):71. doi: 10.1186/s12968-015-0172-7.
    
    2015 Aug 09
    
-   Publication
    
    ### [Non-contrast-enhanced peripheral angiography using a sliding interleaved cylinder acquisition.](https://www.sutterhealth.org/research/publications/noncontrast-enhance-periph-angiog-use-slincyl-1055312471)
    
    Kwon KT, Kerr AB, Wu HH, Hu BS, Brittain JH, Nishimura DG.
    
    Magn Reson Med. 74(3):727-38. doi: 10.1002/mrm.25452. Epub 2014 Sep 9.
    
    2015 Sep 01
    

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

```json
{"@context":"https://schema.org","@type":"MedicalOrganization","name":"Sutter Health","@id":"https://www.sutterhealth.org/#medicalorganization","url":"https://www.sutterhealth.org","logo":"https://www.sutterhealth.org/static/images/sutter-health-logo.svg","address":{"@type":"PostalAddress","streetAddress":"2200 River Plaza Drive","addressLocality":"Sacramento","addressRegion":"CA","postalCode":"95833","addressCountry":"US"},"areaServed":{"@type":"AdministrativeArea","name":"California"},"sameAs":["https://www.facebook.com/SutterHealth","https://www.instagram.com/sutterhealth/","https://x.com/SutterHealth","https://www.youtube.com/sutterhealth","https://www.linkedin.com/company/sutter-health","https://en.wikipedia.org/wiki/Sutter_Health"]}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","@id":"https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480#breadcrumblist","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.sutterhealth.org/"},{"@type":"ListItem","position":2,"name":"Research","item":"https://www.sutterhealth.org/research"},{"@type":"ListItem","position":3,"name":"Research publications","item":"https://www.sutterhealth.org/research/publications"},{"@type":"ListItem","position":4,"name":"Off-reson-robust velocity-selective magnetizatn prep for MRA"}]}
```

```json
{"@context":"https://schema.org","@type":"MedicalScholarlyArticle","@id":"https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480#medicalscholarlyarticle","name":"Off-resonance-robust velocity-selective magnetization preparation for non-contrast-enhanced peripheral MR angiography.","headline":"Off-reson-robust velocity-selective magnetizatn prep for MRA","abstract":"PURPOSE: To develop a new velocity-selective (VS) excitation pulse sequence which is robust to field inhomogeneity, and demonstrate its application to non-contrast-enhanced peripheral MR angiography (MRA). METHODS: The off-resonance-robust VS saturation pulse is designed by incorporating 180° refocusing pulses into the k-space-based reference design and tailoring sequence parameters in a velocity region of interest. The VS saturation pulse is used as magnetization preparation for non-contrast-enhanced peripheral MRA to suppress background tissues but not arterial blood based on their velocities. Non-contrast-enhanced peripheral MRA using the proposed VS preparation was tested in healthy volunteers and a patient with arterial stenosis. RESULTS: Calf angiograms obtained using the new VS preparation show more uniform background suppression than the reference VS preparation, as demonstrated by larger mean values and smaller standard deviations of artery-to-vein and artery-to-muscle contrast-to-noise ratios (71.0 ± 11.4 and 75.3 ± 12.1 versus 61.7 ± 22.7 and 58.5 ± 27.8). Two-station peripheral MRA using the new VS preparation identifies stenosis of the femoral and popliteal arteries in the patient, as validated by digital subtraction angiography. CONCLUSION: Non-contrast-enhanced MRA using the new VS magnetization preparation can reliably provide high angiographic contrast in the lower extremities with significantly improved immunity to field inhomogeneity.","description":"Non-contrast-enhanced MRA using the new VS magnetization preparation can reliably provide high angiographic contrast in the lower extremities with significantly improved immunity to field inhomogeneity.","keywords":["Cardiovascular Diseases","Disease Management"],"datePublished":"2013-11-01","url":"https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480","inLanguage":"en-US","identifier":[{"@type":"PropertyValue","propertyID":"PMID","value":"23192893"},{"@type":"PropertyValue","propertyID":"DOI","value":"10.1002/mrm.24561"}],"sameAs":["https://pubmed.ncbi.nlm.nih.gov/23192893/","https://doi.org/10.1002/mrm.24561"],"isPartOf":{"@type":"Periodical","name":"Magn Reson Med"},"author":[{"@type":"Person","name":"Shin T"},{"@type":"Person","@id":"https://www.sutterhealth.org/research/investigators/bob-s-hu-md-1049681033","name":"Hu BS","url":"https://www.sutterhealth.org/research/investigators/bob-s-hu-md-1049681033"},{"@type":"Person","name":"Nishimura DG"}],"sourceOrganization":{"@type":"MedicalOrganization","name":"Palo Alto Medical Foundation Research Institute"},"about":[{"@type":"DefinedTerm","name":"Cardiovascular Diseases","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Cardiovascular+Diseases%22%5D%7D%5D&verticalKey=research_publication"},{"@type":"DefinedTerm","name":"Disease Management","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Disease+Management%22%5D%7D%5D&verticalKey=research_publication"}],"mainEntityOfPage":{"@type":"WebPage","@id":"https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480","breadcrumb":{"@id":"https://www.sutterhealth.org/research/publications/off-reson-robust-veloc-select-magnetiz-prep-mra-1055312480#breadcrumblist"}}}
```
