# Percutaneous plating of Weber B fibular fractures.

Saxena A & Yun A.

_J Foot Ankle Surg. pii: S1067-2516(16)30393-3. doi: 10.1053/j.jfas.2016.11.012. \[Epub ahead of print\]_

2017-01-12

## Abstract

The purpose of the present study was to describe a minimally invasive percutaneous technique for plating Weber B distal fibular fractures and to evaluate its efficacy by measuring patient outcomes and hardware removal rates.

The data from 17 patients undergoing percutaneous plating of a distal fibular (Weber B) fracture were prospectively studied. A 4- to 6-hole semitubular plate with 3 screws was used for percutaneously plating. The Roles and Maudsley score was used to assess the patients' activity level.

All fibular fractures had healed clinically and radiographically by 8 weeks after surgery. The postoperative Roles and Maudsley scores had improved significantly. The time required to return to activity was 4.3 ± 2.0 months. Hardware removal was required in 3 patients during the study period, which had an average of almost 4 years postoperatively.

The results of the present study have demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.

[PubMed abstract](https://www.ncbi.nlm.nih.gov/pubmed/28089595)

## Research topics

-   [Disease Management](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Disease+Management%5C%22%22)
-   [Musculoskeletal Disorders](https://www.sutterhealth.org/research-search-results?query=%22%5C%22Musculoskeletal+Disorders%5C%22%22)

## Related publications

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

-   Publication
    
    ### [Fixation of osteoporotic distal fibula fractures: A biomechanical comparison of locking versus conventional plates.](https://www.sutterhealth.org/research/publications/fixation-osteoporotic-distal-fibula-fx-1055312983)
    
    Kim T, Ayturk UM, Haskell A, Miclau T, Puttlitz CM.
    
    J Foot Ankle Surg. 46(1):2-6.
    
    2007 Jan 01
    
-   Publication
    
    ### [Comparison between extracorporeal shockwave therapy, placebo ESWT and endoscopic plantar fasciotomy for the treatment of chronic plantar heel pain in the athlete.](https://www.sutterhealth.org/research/publications/heel-pain-shockwave-tx-endosc-fasciotomy-1055312338)
    
    Saxena A, Fournier M, Gerdesmeyer L, Gollwitzer H.
    
    Muscles Ligaments Tendons J. 2(4):312-6. Print 2012 Oct.
    
    2013 Jan 21
    
-   Publication
    
    ### [Medial locking plate versus screw fixation for fixation of the Ludloff osteotomy.](https://www.sutterhealth.org/research/publications/lock-plate-vs-screw-ludloff-osteotomy-1055312352)
    
    Saxena A, St Louis M.
    
    J Foot Ankle Surg. 52(2):153-7. doi: 10.1053/j.jfas.2012.11.005. Epub 2013 Jan 16.
    
    2013 Mar 01
    
-   Publication
    
    ### [External auditory exostoses: evaluation and treatment.](https://www.sutterhealth.org/research/publications/external-auditory-exostoses-evaluation-treatment-1055312964)
    
    Hetzler DG.
    
    Otolaryngol Head Neck Surg. 139(3):482; author reply 482. doi: 10.1016/j.otohns.2008.05.629.
    
    2008 Sep 01
    
-   Publication
    
    ### [Comment on: "Outcomes of Drill Canalplasty in Exostoses and Osteoma: Analysis of 256 Cases and Literature Review."](https://www.sutterhealth.org/research/publications/comment-outcomes-drill-canalplasty-exotoses-1055312315)
    
    Hetzler DG.
    
    Otol Neurotol. doi: 10.1097/MAO.0000000000001383. \[Epub ahead of print\]
    
    2017 Mar 22
    

[View all publications](https://www.sutterhealth.org/research-search-results?verticalKey=research_publication)

```json
{"@context":"https://schema.org","@type":"MedicalOrganization","name":"Sutter Health","@id":"https://www.sutterhealth.org/#medicalorganization","url":"https://www.sutterhealth.org","logo":"https://www.sutterhealth.org/static/images/sutter-health-logo.svg","address":{"@type":"PostalAddress","streetAddress":"2200 River Plaza Drive","addressLocality":"Sacramento","addressRegion":"CA","postalCode":"95833","addressCountry":"US"},"areaServed":{"@type":"AdministrativeArea","name":"California"},"sameAs":["https://www.facebook.com/SutterHealth","https://www.instagram.com/sutterhealth/","https://x.com/SutterHealth","https://www.youtube.com/sutterhealth","https://www.linkedin.com/company/sutter-health","https://en.wikipedia.org/wiki/Sutter_Health"]}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373#breadcrumblist","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.sutterhealth.org/"},{"@type":"ListItem","position":2,"name":"Research","item":"https://www.sutterhealth.org/research"},{"@type":"ListItem","position":3,"name":"Research publications","item":"https://www.sutterhealth.org/research/publications"},{"@type":"ListItem","position":4,"name":"Percutaneous plating of Weber B fibular fractures."}]}
```

```json
{"@context":"https://schema.org","@type":"MedicalScholarlyArticle","@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373#medicalscholarlyarticle","name":"Percutaneous plating of Weber B fibular fractures.","headline":"Percutaneous plating of Weber B fibular fractures.","abstract":"The purpose of the present study was to describe a minimally invasive percutaneous technique for plating Weber B distal fibular fractures and to evaluate its efficacy by measuring patient outcomes and hardware removal rates. The data from 17 patients undergoing percutaneous plating of a distal fibular (Weber B) fracture were prospectively studied. A 4- to 6-hole semitubular plate with 3 screws was used for percutaneously plating. The Roles and Maudsley score was used to assess the patients' activity level. All fibular fractures had healed clinically and radiographically by 8 weeks after surgery. The postoperative Roles and Maudsley scores had improved significantly. The time required to return to activity was 4.3 ± 2.0 months. Hardware removal was required in 3 patients during the study period, which had an average of almost 4 years postoperatively. The results of the present study have demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.","description":"Results from 17 patients demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.","keywords":["Disease Management","Musculoskeletal Disorders"],"datePublished":"2017-01-12","url":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373","inLanguage":"en-US","identifier":[{"@type":"PropertyValue","propertyID":"PMID","value":"28089595"},{"@type":"PropertyValue","propertyID":"DOI","value":"10.1053/j.jfas.2016.11.012"}],"sameAs":["https://pubmed.ncbi.nlm.nih.gov/28089595/","https://doi.org/10.1053/j.jfas.2016.11.012"],"isPartOf":{"@type":"Periodical","name":"J Foot Ankle Surg"},"author":[{"@type":"Person","name":"Saxena A"},{"@type":"Person","name":"Yun A"}],"sourceOrganization":{"@type":"MedicalOrganization","name":"Palo Alto Medical Foundation Research Institute"},"about":[{"@type":"DefinedTerm","name":"Disease Management","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Disease+Management%22%5D%7D%5D&verticalKey=research_publication"},{"@type":"DefinedTerm","name":"Musculoskeletal Disorders","url":"https://www.sutterhealth.org/research-search-results?facets=%5B%7B%22i%22%3A%22c_researchTopics.name%22%2C%22v%22%3A%5B%22Musculoskeletal+Disorders%22%5D%7D%5D&verticalKey=research_publication"}],"mainEntityOfPage":{"@type":"WebPage","@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373","breadcrumb":{"@id":"https://www.sutterhealth.org/research/publications/percutaneous-plate-weber-b-fibula-fx-1055312373#breadcrumblist"}}}
```