Percutaneous plating of Weber B fibular fractures.
Abstract
The purpose of the present study was to describe a minimally invasive percutaneous technique for plating Weber B distal fibular fractures and to evaluate its efficacy by measuring patient outcomes and hardware removal rates.
The data from 17 patients undergoing percutaneous plating of a distal fibular (Weber B) fracture were prospectively studied. A 4- to 6-hole semitubular plate with 3 screws was used for percutaneously plating. The Roles and Maudsley score was used to assess the patients' activity level.
All fibular fractures had healed clinically and radiographically by 8 weeks after surgery. The postoperative Roles and Maudsley scores had improved significantly. The time required to return to activity was 4.3 ± 2.0 months. Hardware removal was required in 3 patients during the study period, which had an average of almost 4 years postoperatively.
The results of the present study have demonstrated that percutaneous plating is an effective surgical option for treating Weber B distal fibular fractures.
Research topics
Related publications
View all publications- Palanca A, Mann RA, Mann JA, Haskell A.Foot Ankle Int. 39(2):135-142. doi: 10.1177/1071100717738747.2018 Feb 01
- Saxena A, Hofer D.J Foot Ankle Surg. pii: S1067-2516(17)30537-9. doi: 10.1053/j.jfas.2017.08.024. [Epub ahead of print]2017 Dec 01
- Gerdesmeyer L, Saxena A, Klueter T, Harrasser N, Fullem B, Krath A.J Foot Ankle Surg. 56(5):964-967. doi: 10.1053/j.jfas.2017.06.014.2017 Sep 01
- Publication
Triple Achilles tendon rupture: case report.
Saxena A, Hofer D.J Foot Ankle Surg. pii: S1067-2516(17)30536-7. doi: 10.1053/j.jfas.2017.08.023. [Epub ahead of print]2017 Nov 16 - Saxena A, Yun A, Patel R, Gerdesmeyer L, Maffulli N.J Foot Ankle Surg. pii: S1067-2516(16)30186-7. doi: 10.1053/j.jfas.2016.07.024. [Epub ahead of print] Send to2016 Sep 08