Nonrigid motion correction with 3D image-based navigators for coronary MR angiography.
Abstract
PURPOSE: To develop a retrospective nonrigid motion-correction method based on 3D image-based navigators (iNAVs) for free-breathing whole-heart coronary magnetic resonance angiography (MRA).
METHODS: The proposed method detects global rigid-body motion and localized nonrigid motion from 3D iNAVs and compensates them with an autofocusing algorithm. To model the global motion, 3D rotation and translation are estimated from the 3D iNAVs. Two sets of localized nonrigid motions are obtained from deformation fields between 3D iNAVs and reconstructed binned images, respectively. A bank of motion-corrected images is generated and the final image is assembled pixel-by-pixel by selecting the best focused pixel from this bank. In vivo studies with six healthy volunteers were conducted to compare the performance of the proposed method with 3D translational motion correction and no correction.
RESULTS: In vivo studies showed that compared to no correction, 3D translational motion correction and the proposed method increased the vessel sharpness by 13% ± 13% and 19% ± 16%, respectively. Out of 90 vessel segments, 75 segments showed improvement with the proposed method compared to 3D translational correction.
CONCLUSION: We have developed a nonrigid motion-correction method based on 3D iNAVs and an autofocusing algorithm that improves the vessel sharpness of free-breathing whole-heart coronary MRA.
Research topics
Related publications
View all publications- Gaudiani VA, Grunkemeier GL, Castro LJ, Fisher AL, Wu Y.Heart Surg Forum. 7(4):E337-42.2004 Jan 01
- Osnabrugge RL, Arnold SV, Reynolds MR, Magnuson EA, Wang K, Gaudiani VA, Stoler RC, Burdon TA, Kleiman N, Reardon MJ, Adams DH, Popma JJ, Cohen DJ; CoreValve U.S. Trial Investigators.JACC Cardiovasc Interv. 8(2):315-23. doi: 10.1016/j.jcin.2014.08.016.2015 Feb 01
- Addy NO, Ingle RR, Wu HH, Hu BS, Nishimura DG.Magn Reson Med. 74(3):614-21. doi: 10.1002/mrm.25803. Epub 2015 Jul 14.2015 Sep 01
- Nayak KS, Nielsen JF, Bernstein MA, Markl M, D Gatehouse P, M Botnar R, Saloner D, Lorenz C, Wen H, S Hu B, Epstein FH, N Oshinski J, Raman SV.J Cardiovasc Magn Reson. 17(1):71. doi: 10.1186/s12968-015-0172-7.2015 Aug 09
- Publication
Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.
Ingle RR, Wu HH, Addy NO, Cheng JY, Yang PC, Hu BS, Nishimura DG.Magn Reson Med. 72(2):347-61. doi: 10.1002/mrm.24924. Epub 2013 Sep 4.2014 Aug 01




