Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.
Abstract
PURPOSE: To implement a nonrigid autofocus motion correction technique to improve respiratory motion correction of free-breathing whole-heart coronary magnetic resonance angiography acquisitions using an image-navigated 3D cones sequence.
METHODS: 2D image navigators acquired every heartbeat are used to measure superior-inferior, anterior-posterior, and right-left translation of the heart during a free-breathing coronary magnetic resonance angiography scan using a 3D cones readout trajectory. Various tidal respiratory motion patterns are modeled by independently scaling the three measured displacement trajectories. These scaled motion trajectories are used for 3D translational compensation of the acquired data, and a bank of motion-compensated images is reconstructed. From this bank, a gradient entropy focusing metric is used to generate a nonrigid motion-corrected image on a pixel-by-pixel basis. The performance of the autofocus motion correction technique is compared with rigid-body translational correction and no correction in phantom, volunteer, and patient studies.
RESULTS: Nonrigid autofocus motion correction yields improved image quality compared to rigid-body-corrected images and uncorrected images. Quantitative vessel sharpness measurements indicate superiority of the proposed technique in 14 out of 15 coronary segments from three patient and two volunteer studies.
CONCLUSION: The proposed technique corrects nonrigid motion artifacts in free-breathing 3D cones acquisitions, improving image quality compared to rigid-body motion correction.
Research topics
Related publications
View all publications- Shin T, Lustig M, Nishimura DG, Hu BS.J Magn Reson Imaging. 40(6):1496-502. doi: 10.1002/jmri.24494. Epub 2013 Nov 15. J Magn Reson Imaging. 40(6):1496-502. doi: 10.1002/jmri.24494. Epub 2013 Nov 15. Send to:2014 Dec 02
- Publication
Non-contrast-enhanced peripheral angiography using a sliding interleaved cylinder acquisition.
Kwon KT, Kerr AB, Wu HH, Hu BS, Brittain JH, Nishimura DG.Magn Reson Med. 74(3):727-38. doi: 10.1002/mrm.25452. Epub 2014 Sep 9.2015 Sep 01 - Osnabrugge RL, Arnold SV, Reynolds MR, Magnuson EA, Wang K, Gaudiani VA, Stoler RC, Burdon TA, Kleiman N, Reardon MJ, Adams DH, Popma JJ, Cohen DJ; CoreValve U.S. Trial Investigators.JACC Cardiovasc Interv. 8(2):315-23. doi: 10.1016/j.jcin.2014.08.016.2015 Feb 01
- Gaudiani VA, Grunkemeier GL, Castro LJ, Fisher AL, Wu Y.Heart Surg Forum. 7(4):E337-42.2004 Jan 01
- Asch DA, Troxel AB, Stewart WF, Sequist TD, Jones JB, Hirsch AG, Hoffer K, Zhu J, Wang W, Hodlofski A, Frasch AB, Weiner MG, Finnerty DD, Rosenthal MB, Gangemi K, Volpp KG.JAMA. 314(18):1926-35. doi: 10.1001/jama.2015.14850.2015 Nov 10




